Decision Center
The Decision Center shows saved decisions, unresolved alerts, and alert history. Where Work order review is available, an authorized operator can review the evidence, save a draft, and separately confirm creation of a maintenance work order. Assignment, field execution, and completion records continue in the linked work order.
Prerequisites and inputs
Access requires permission to view Semiconductor Operations for the current tenant. The page brings together saved decisions, alerts, and linked work orders. Open the equipment and alert details to verify measurements, source timestamps, and data quality before starting the review.
Review a decision
- Open Decision Center and choose All or Pending.
- Expand a record to inspect its description, saved recommendation, and current status.
- Use Refresh to load the latest records.
A saved recommendation helps prepare a maintenance response. Check the affected equipment, measurements, and operating conditions, then complete the site approval process before handing confirmed tasks to the maintenance team.
Review alerts and work orders
The Recent Alerts table shows unresolved alerts and their observation times. Confirm the operating period, then review the recorded Suggested action and linked work-order number. When the suggested action is empty, open the alert details and use equipment status and measurement records to determine the next step.
The History table shows alerts from the last seven days and the number of linked work orders. Expand the record to review its original description. Use the linked work-order number to continue the maintenance workflow.
Review and create a work order
- Open Work order review for an unresolved alert. Check the equipment, observation time, detection method, and recorded evidence.
- Check the sampling period and sources covered by the evidence. For fault or repair-effectiveness investigations, gather the corresponding raw measurements and maintenance records.
- Select the available reference procedure and open it to check its version, content, applicability, and approval status. Draft documents support preparation and review; field work follows the approved procedure version.
- Enter a title, description, and priority. Confirm that you have read the evidence notes, then save and review the work-order draft.
- Check the draft and explicitly confirm work-order creation. Creation requires the existing Semiconductor Operations edit and work-order create/view permissions.
- Open the returned work-order number. Refresh the review to read its current status; continue assignment, execution, and completion in the work-order workflow.
If the evidence or procedure version changes, review the updated information before confirming again. If a request is interrupted, reopen the saved decision and check the linked work order before continuing. Repeating a successful confirmation returns the work order already created for that decision.
Expected result and validation
The result is a review of the saved record, alert status, and existing work-order links. Check that the alert concerns the intended equipment, its timestamp falls within the operating period under review, and the work-order number opens the expected authorized record. When a link or suggested action is empty, continue the alert review and work-order preparation.
Handoff and records
- After confirming creation, use the linked work order for assignment, maintenance, and completion records. Follow the site workflow for SOP approval and equipment operation.
- Before saving a draft, select an applicable procedure and check its version, content, and approval status. If the list is empty, ask an administrator to configure an applicable procedure, then continue the review.
- The decision list shows saved records; use the linked work-order status to follow task progress.
- Include measurement evidence, recommendations, and operator review results in the handoff.
If records or alerts fail to load, refresh once and contact an administrator if the error persists. Resume the alert and work-order review after data loading is restored.
Continue With AI Agent
Choose Ask AI in an alert review to open a new conversation with the equipment reference and an editable question identifying the alert. Review and edit the question, then send it manually to begin. This entry belongs to the alert-review stage; continue work-order drafts through the review form.
With the relevant tools enabled, the assistant can retrieve stored alert evidence and applicable procedure-version references. Check observation times, data coverage, and procedure versions in the answer, then open the referenced documents to review their content and approval status. Use raw measurements and maintenance records for fault investigations; return to the alert review to check sources when more evidence is needed.
On the equipment-health page, select the equipment and choose Ask AI to open a new conversation. Workspaces with equipment context enabled attach the selected equipment. Check the equipment reference, enter a question, and send it explicitly. In a general conversation, include the equipment and time period in your question.
Before using an answer, check the equipment, period, referenced sources, and observation times. For questions about a specific alert or SOP, identify the alert and procedure version and review the corresponding measurement evidence. Create and confirm work orders through the review form described above.
Wait for equipment data to finish loading before opening the assistant. For equipment-scoped conversations, ask the administrator to confirm that equipment context is enabled for the workspace. If the entry remains unavailable, contact the administrator with the equipment name and page details.